Shipra Venture proudly promotes Kabson Fire and Alwin Fire — two renowned brands in fire safety and protection united under one trusted name.

Fire Extinguisher Refilling & Replacement

Stay Ready for Emergencies with Timely Refilling

Fire extinguishers are the first line of defense against fire hazards—only if they’re charged, functional, and ready. At Shipra Venture, we specialize in certified fire extinguisher refilling services in Kolkata, backed by ISO 9001 standards, BIS compliance, and a state-of-the-art refilling workshop.

We handle everything from inspection and refilling to pres

Types of Fire Extinguishers We Refill

We service and refill all major fire extinguisher types, using ISI, CE, and UL-approved agents:

ABC Dry Powder (Class A, B, C & Electrical)

CO₂ (Class B & Electrical)

Foam (AFFF & Mechanical)

Clean Agent (FE-36, HFC-236fa)

Water Mist / Stored Pressure Water

Our 10-Step Refilling Process

Every extinguisher that enters our facility is handled with the highest degree of care, compliance, and quality control:

01

Depressurization & Agent Removal

Ensuring complete discharge of old contents.

02

Valve Dismantling & Cleaning

Includes siphon tube removal and internal cleaning.

03

O-Ring & Spring Replacement

To ensure future pressure retention and safety.

04

Visual Internal & External Inspection

To detect rust, dents, or compromised structure.

05

Reassembly with New Valve Components

Using OEM-compatible parts.

06

Refilling with Approved Agent by Weight

According to unit type and size.

07

Re-pressurization Using Calibrated Gas

Ensuring correct PSI as per standards.

08

Leak Testing & Nozzle Attachment

Complete nozzle/hose reinstallation and pressure testing.

09

Weighing & Verification

Cross-checking tolerance against manufacturer specs.

10

Tagging, Sealing & Certification

New tamper-proof seal, recharge label, and warranty documentation.

When Is Refilling Required?

Knowing when to refill your fire extinguisher is crucial to maintaining safety:

1. 🔁 After Every Use
Even partial discharge reduces pressure levels and agent effectiveness. Refill immediately after use.

2. ⚠️ After Partial Discharge or Pressure Drop
If your pressure gauge is in the red zone or you’ve had an incomplete discharge, it’s time to refill.

3. 🗓️ Scheduled Maintenance (Every 5 Years)
IS 2190 recommends that extinguishers be refilled every 5 years, even if unused, to maintain internal stability.

4. 🧑‍🔧 Annual Maintenance Checkups
A yearly inspection by a certified technician will determine whether a refill is required.

5. 📜 Legal & Safety Compliance
Non-compliance can result in penalties or failure during emergencies. Refilling ensures you’re audit-ready.

Service Warranty

We offer refill warranties depending on the fire extinguisher type and AMC plan:

3-Year Warranty

5-Year Extended Warranty

6-Year Under AMC with Quarterly Checks

Complimentary With Refilling

Educational Insight: Why Refilling Matters

Many underestimate the importance of fire extinguisher upkeep. A fully discharged or expired extinguisher can be more dangerous than no extinguisher at all. It’s not just about having it—it must work in those critical seconds. Fire safety laws in India require proper maintenance and refilling to prevent business and life loss.

Certified Excellence You Can Trust

Get in Touch – Book Your Refilling Today

Shipra Venture – Fire Extinguisher Refilling & Fire Safety Services

Inquiry Now